Brand Name : Envsin

Model Number : ETCZ4010

Certification : CE and ISO

Place of Origin : China

MOQ : 1

Price : To Be Negotiated

Payment Terms : L/C, T/T, Western Union

Supply Ability : 25 per month

Delivery Time : 30-35 business days after received the payment

Packaging Details : Wooden packing

Product name : Environmental Test Chamber

Test Space : 8m³

Internal size : 2000W×2000D×2056H (mm)

External size : 2240Wx2240Dx3800H (mm)

Power supply : AC230V/400V,50Hz±1, 60A, 3/N/PE, earth resistance < 4Ω

Max. Power : 33KW

Max. Currency : 60A

Cooling Method : Water-Cooled(Cooling system)

Contact Now

8m³ Environmental Test Chamber Water-Cooled Walk In Environmental Test Room

Designed for high and low temperature test and rapid temperature change ESS test for whole product, machine component, and materials.

This machine can test samples of or not of thermal dispersion. For samples of thermal dispersion, the thermal dispersion power should be no more than the refrigerating power of the test chamber. The thermal conditioning process is dynamic, and the refrigerating power varies in different temperature. Therefore if the samples are of easy thermal dispersion, please refer to the load thermal capacity graph blow for a correct test performance.

Properties:

Test Space

8m³

Internal size

2000W×2000D×2056H (mm)

External size

2240Wx2240Dx3800H (mm)

External size

Walk-in Temperature Humidity Chamber with Advanced Data Logging for Large-Scale Testing

Power supply

AC230V/400V,50Hz±1, 60A, 3/N/PE, earth resistance < 4Ω

Max. Power

33KW

Max. Currency

60A

Cooling Method

Water-Cooled(Cooling system)

Installation Site

  • Installation ground is flat, of good ventilation; no flammable article, corrosive gas or dust
  • No strong EMR source nearby
  • Close to drainage system ( within 2 meters for condensate water)
  • The chamber should be installed on a flat floor, the load of the surface is more than 10000kg/m2
  • Prepare proper power supply and water supply
  • Prepare gas if it is needed
  • Ambient Temp: 5℃~25℃suggested, 25℃~35℃ function normally (for air-cooled model);5℃~40℃ function normally (for water-cooled model)
  • Ambient Humid:≤85%RH
  • Ambient Pressure:86KPa~106KPa
  • Installation space assurances, as following

Walk-in Temperature Humidity Chamber with Advanced Data Logging for Large-Scale Testing

Specifications:

Temp.&Humid. Parm.

Temp. Range:-40℃~+100℃

Note:

1.Test with no load, meeting GB/T5170-2008, if no other special notice.

2.Ambient Temp 25℃, good ventilation condition: function well if 35℃≥RT>25℃;Cool down rate and thermal load capacity will be affected by ambient low temperature.

3.Water-cooled water temp ≤28℃, water pressure is 0.3MPa~0.6Mpa, water pressure difference is ≥0.2Mpa.

Temp. Uniformity:±0.5℃~±2.0℃
Temp Deviation:±0.1℃~±2.0℃
Temp Fluctuation:±0.1℃~±0.5℃
Temp Gradient:<2.0℃
Heat up Rate:4K/min
Cool down Rate:4K/min

Climate Test










Temp. Range:+10℃~+95℃
Humid. Range: 10%RH~98%RH
Humid. Fluctuation: ±1.0℃~±3.0℃
Temp. Uniformity: ±0.5℃~±2.0℃
Humid. Uniformity: ±1.0%RH~±5.0%RH
Temp. Deviation: ±0.1℃~±2.0℃
Humid. Deviation: ±1.0%RH~±5.0%RH
Temp. Fluctuation: ±0.1℃~±0.5℃
Humid.Fluctuation:±1.0%RH~±3.0%RH
Temp. Gradient: <2.0℃
Humid. Gradient: <5.0%RH
Test Standards

1. GB/T 2423.1 Low Temp. Test Method

2. GB/T 2423.2 High Temp. Test Method

3. GB/T2423.34 Temp. and Humid Cycling Test Method

4. IEC60068-2 Temp. and Humid Test Method

5. GJB 150.3 High Temp. Test Method

6. GJB 150.4 Low Temp. Test Method

7. GJB 150.9 Temp. and Humid Cycling Test Method

8. MIL-STD-202G-103B Humid. Test Method

Load thermal capacity graph (calorific value of specimen) In temperature test, the thermal capacity for loading varies from different temperature value.
Temperature and Humidity Control Chart Walk-in Temperature Humidity Chamber with Advanced Data Logging for Large-Scale Testing

Factory Overview:
Envsin Instrument Equipment Co., Ltd is one leading manufacturer and supplier in China for environmental chamber and climatic chamber.
Envsin has won more than 67 patents,24 software copyright,ISO9001:2008 and ISO 14001:2004 are certified.
Walk-in Temperature Humidity Chamber with Advanced Data Logging for Large-Scale Testing
Envsin equipment are widely used with the Aviation,Aerospace ,Boat and Ship,Military,Rail Transit,Medical,Communication,New Energy,
Plateau,Civil Electrical,Military,Electronics,Package,Automotive,Military Vehicles,Instrument,Fire Equipment.Envsin products include: Temperature Humidity Chamber,Thermal Shock Chamber,Industrial Oven,Aging Test Chamber,Corrosion
Test Chamber,Mechanical Tester.
Walk-in Temperature Humidity Chamber with Advanced Data Logging for Large-Scale Testing
During past years, we are honored to be the preferential vendor to many famous entities such as Foxconn, Apple,CISCO,SAMSUNG.With 18 service centers in 16 countries,envsin is qualified to provide you competitive test solutions and services.
Walk-in Temperature Humidity Chamber with Advanced Data Logging for Large-Scale Testing

Product Tags:

8m3 Environmental Test Chamber

      

230V Walk In Test Chamber

      

CE Walk In Test Chamber

      
Wholesale Walk-in Temperature Humidity Chamber with Advanced Data Logging for Large-Scale Testing from china suppliers

Walk-in Temperature Humidity Chamber with Advanced Data Logging for Large-Scale Testing Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Envsin Instrument Equipment Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)